ES F16F-J4000-R
		
	  The FC-to-FC (4Gbps) SBOD (Switched Bunch of Drives) is designed for drive expansion with the FF or F16F RAID enclosures. The loop switched architecture improves drive loop performance across Fibre Channel dual-loops.
- Highlights
 - Specifications
 - Accessories
 
- Expansion enclosure for Fibre-to-Fibre RAID systems
 - Controllers with loop switches dynamically distribute data to individual disks
 - Highest density, 16 drives in 3U rack space
 - Redundant SBOD controllers
 - Fault-tolerant dual-loop connectivity
 - Two (2) 4G FC ports per controller
 - Diagnostics LED panel
 - Proprietary enclosure service via in-band connections with the managing RAID enclosure
 
| Host-to-Drive Interface | SBOD Model | Corresponding RAID Subsystem(s) | Configuration | Form Factor | |
|---|---|---|---|---|---|
| Model | Max. Connection | ||||
| 4G FC to 4G FC | F16F-J4000-R | 
								FF-R4030 FF-S4030  | 
							7 + 7 SBODs | Redundant loop-switched controllers | 3U rack- mount | 
| 
								F16F-R4031-4 F16F-S4031-4  | 
							6 SBODs | ||||
| 
								F16F-R4031-6 F16F-S4031-6  | 
							6 +7 SBODs | ||||
Host Interface
- Two (2) 4G FC ports per controller
 - SES enclosure service via in-band methodology
 
Drive Interface
- Sixteen (16) hot swappable 4G FC disk drives
 
System Components
- Redundant SBOD controller configurations
 - Fault-tolerant modules interfaced through a common backplane
 - Redundant, hot swappable 530W power supply units
 - Redundant, dual-speed cooling modules
 - LED diagnostic panel
 - Easy-to-use rotary ID switch to set AL_PA
 
Management
- Management of multiple enclosures via RAID firmware and/or through GUI
 - Module status LED indicators:
 - Six (6) on LED panel (1 service LED and 5 status LEDs)
 - Two (2) per drive tray
 - Three (3) per controller module (1 Ready/Failed LED and two (2) Link status LEDs)
 - One (1) per power supply unit
 - Two (2) per cooling module
 
Physical / Electrical
Interface
- Host Interface: Two (2) SPF ports per SBOD controller.
 - Drive Interface: 4G FC
 
Power Supply Module
| Power Requirements | |
|---|---|
| Input Voltage | 
								100VAC @ 9A 240VAC @ 4.5A with PFC (auto-switching)  | 
						
| Frequency | 47 to 63Hz | 
| Power Consumption | 530W | 
Cooling Module
| Specifications | |
|---|---|
| Speed | High or low rotation speed controlled by firmware proactive mechanisms | 
| Max. Airflow (each module) | 
								High speed: 90CFM Low speed: 70.7CFM  | 
						
Environmental Specifications
| Humidity | 
								
  | 
						
|---|---|
| Temperature | 
								
  | 
						
| Altitude | 
								
  | 
						
Dimensions
| Dimensions | 
								With Forearm Handles (Not including rear-end protrusions)  | 
							Without Forearm Handles | 
|---|---|---|
| Height | 131mm (5.2 inches) | 130mm (5.1 inches) | 
| Width | 482.6mm (19 inches) | 445mm (17.5 inches) | 
| Length | 504.3mm (19.8 inches) | 488.2mm (19.2 inches) | 
System weight
- Net Weight: 33kg (72.6 pounds)
 - Gross Weight: 35kg (77 pounds)
 
Spare Parts
| 
								 | 
							IFT-9273F4JIO2 | 4G-FC to 4G-FC SES SBOD controller module, 2 FC ports | 
|---|---|---|
| 
								 | 
							IFT-9373CDTray | 3.5" Hard disk drive tray | 
| 
								 | 
							IFT-9273ECPSU | Power supply module for EonStor 3U series, ASIC400 series subsystems, 530W capacity | 
| 
								 | 
							IFT-9273ECFanMod | Cooling fan module for EonStor, ASIC400, and 3U-profile series subsystems | 
Accessories
| 
								 | 
							IFT-9270CSFP4GA01 | Agilent Fibre Channel 4.25/2.125/1.0625 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode | 
|---|---|---|
| 
								 | 
							IFT-9270CFCCab01 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mmx2, 1 Meter | 
| 
								 | 
							IFT-9270CFCCab02 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mmx2, 5 Meters | 
| 
								 | 
							IFT-9270CFCCab03 | Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mmx2, 10 Meters | 
| 
								 | 
							IFT-9273CSlider32 | Slide rail assembly, for Enhanced ES 3U/16-bay subsystem, 23"~32" rack depth | 
| 
								 | 
							IFT-9273CSlider36 | Slide rail assembly, for Enhanced ES 3U/16-bay subsystem, 23"~36" rack depth | 